Skip to content

Lighting & Emission Testing Equipment

Engine speed analyzer | MQZ-2/4/5/6

MQZ engine speed analyzers use cigarette-lighter socket or battery signals, vibration, supporting acoustic signals or OBD data. The MQZ-2, 4 and 5 measure 500–6,000 r/min for independent use or operation alongside an exhaust gas analyzer, with model-specific engine and interface requirements.

Product Overview

MQZ engine speed analyzers measure vehicle engine speed for use at vehicle emissions inspection stations. They can be used independently or alongside an exhaust gas analyzer. Depending on the model, speed is obtained from cigarette-lighter socket signals, battery signals, vibration, supporting acoustic signals or OBD data, providing different connection options for the vehicle and test site.

The MQZ-2, MQZ-4 and MQZ-5 all measure 500–6,000 r/min, but their signal acquisition methods and engine compatibility differ. Start with the preferred connection point—the vehicle's interior socket, battery or engine—and match it to the applicable model.

Models and Measurement Methods

MQZ-2: Cigarette-Lighter Socket or Battery Signals

The MQZ-2 determines engine speed from signal variations at the vehicle's cigarette-lighter socket or battery. It is suitable for four-stroke engines with 1–12 cylinders. The connector can be inserted into the interior cigarette-lighter socket. If accurate measurement cannot be obtained there, battery clips provide an alternative signal connection at the vehicle battery.

The instrument uses DSP digital processing and offers multiple signal outputs for connection to associated testing equipment.

MQZ-4: Vibration Measurement and OBD Reading

The MQZ-4 can acquire engine vibration signals or read engine speed through the vehicle's OBD interface. Vibration measurement is intended for four-stroke, four-cylinder engines, with the measuring component attached to a bolt on the engine block. OBD measurement uses a standard OBDII interface.

MQZ-5: Combined Vibration and Acoustic Measurement

The MQZ-5 combines vibration signals with supporting acoustic measurement for four-stroke engines. The measuring component attaches to a bolt on the engine block, and ARM digital processing produces engine-speed data. It can be used for independent speed measurement or alongside exhaust testing equipment.

The MQZ-5 has a data refresh interval of 0.1 s, a response time of less than 1 s and an initialization time of less than 10 s. An external power supply supports continuous measurement for tests requiring ongoing engine-speed readings.

Please contact us for MQZ-6 configuration and availability.

Technical Specifications

ParameterMQZ-2MQZ-4MQZ-5
Measurement methodCigarette-lighter socket or battery signalsVibration or OBD readingVibration with supporting acoustic signals
CompatibilityFour-stroke engines, 1–12 cylindersVibration: four-stroke, four-cylinder engines; OBD: standard OBDII interface supportFour-stroke engines
Measurement range500–6,000 r/min500–6,000 r/min500–6,000 r/min
Indication error<1%±1%<1%
Response time<1 s<1 s<1 s
Data refresh interval0.1 s0.25 s0.1 s
Baud rate960096009600
Operating voltageDC 12 V (9–15 V)DC 12 V (9–15 V)DC 12 V (9–15 V)
Operating current500 mA500 mA400 mA
Dimensions (L × W × H)144 × 98 × 40 mm144 × 98 × 40 mm185 × 148 × 43 mm

All three models operate at an ambient temperature of 0–45 ℃, atmospheric pressure of 86–106 kPa and relative humidity of 30%–90%.

Use with Exhaust Testing Equipment

When engine-speed readings are required during exhaust testing, the appropriate model can be used with an exhaust gas analyzer. The MQZ-2, 4 and 5 offer multiple signal outputs for use with related Cartesy testing equipment. They can also be used for independent engine-speed measurement.

Frequently Asked Questions

What If the MQZ-2 Does Not Measure Accurately from the Cigarette-Lighter Socket?

Battery clips can be used to acquire the signal at the vehicle battery instead. Both methods measure engine speed; make the connection according to the equipment's operating instructions.

Can the MQZ-4 Vibration Method Be Used on Every Engine?

Vibration measurement is intended for four-stroke, four-cylinder engines. The MQZ-4 can also read speed through a standard OBDII interface, provided the vehicle supports the corresponding communication.

Where Is the MQZ-5 Measuring Component Attached?

It attaches to a bolt on the engine block. The instrument combines vibration and supporting acoustic signals to measure speed on four-stroke engines.

Must These Instruments Be Used with an Exhaust Gas Analyzer?

The MQZ-2, 4 and 5 can measure engine speed independently or work alongside an exhaust gas analyzer, depending on the test station's tasks.

Contact Us

Tell Cartesy about the vehicle types, engine stroke cycle and cylinder count, preferred signal acquisition method and associated test equipment. We can help select the appropriate model.

Request a Quote

Request configuration and pricing for your project.

Share your vehicle type, inspection lane layout, target capacity, and required model configuration for Engine speed analyzer | MQZ-2/4/5/6.

Share the project location, vehicle types, inspection scope, applicable standards, target throughput, site conditions and current stage. We will confirm the configuration scope before discussing pricing.