Lighting & Emission Testing Equipment
Automotive Exhaust Gas Analyzer | MQW-50A/50B/5105/5102/511/411/311
The MQW automotive exhaust gas analyzer range includes models for two-speed idle, steady-state, transient and diesel emissions testing. Model-specific options include infrared or electrochemical measurement, RS-232 communication, NOx conversion, an external smoke meter connection and optional printing.
Product Overview
MQW automotive exhaust gas analyzers measure the gas components in vehicle exhaust for inspection stations, vehicle manufacturers and repair workshops. The range includes models for two-speed idle, steady-state and simplified transient testing, as well as configurations for diesel emissions testing.
Gas channels, NO measurement principles and supporting functions vary by model. The following comparison covers multi-gas analysis for petrol vehicles, CO₂ and NO measurement for diesel vehicles, and standalone idle testing.
Models and Main Functions
| Model | Measurement and configuration | Main application |
|---|---|---|
| MQW-50A | Measures HC, CO, CO₂, NO and O₂; electrochemical NO and O₂ measurement | Two-speed idle exhaust testing |
| MQW-50B | Measures HC, CO, CO₂, NO and O₂; non-dispersive infrared NO measurement | Steady-state exhaust testing |
| MQW-5105 | Measures HC, CO, CO₂, NO and O₂; non-dispersive infrared NO measurement with NOx conversion | Simplified transient exhaust testing |
| MQW-5102 | Non-dispersive infrared measurement of CO₂ and NO, with NOx conversion; connects to an MQY-202 opacity meter | Equipment for diesel emissions testing |
| MQW-511/411/311 | Standalone idle and two-speed idle testing; optional internal or external microprinter | Inspection stations and automotive or motorcycle workshops |
When selecting an MQW-511, 411 or 311, specify the gases to be measured so that the appropriate model and gas-channel configuration can be identified.
Product Features
Measurement Principles Matched to the Test
The MQW-50A, 50B and 5105 use non-dispersive infrared measurement for HC, CO and CO₂, and electrochemical measurement for O₂. The 50A measures NO electrochemically, while the 50B and 5105 use non-dispersive infrared measurement for NO. These three models also calculate the excess-air ratio λ from the measured CO, CO₂, HC and O₂ values.
The MQW-5105 and 5102 use NOx conversion technology to convert NO₂ to NO for measurement. The MQW-5102 can be used with an external smoke meter for projects requiring both gas-component and exhaust-opacity measurements.
Sample Filtration and Everyday Operation
The MQW-50A and 50B include a sampling pump and filtration system, with automatic zeroing. The MQW-5105, 5102 and 511/411/311 series use multi-stage filtration to reduce sensor contamination from the sampled gas. The 511/411/311 series also supports automatic zeroing.
Graphical, menu-based interfaces support everyday testing. The 5105 and 5102 use a main unit with a separate sample-preconditioning unit; their dimensions and power consumption are listed separately below.
PC Connection and Result Output
All listed models support PC communication through RS-232. For standalone testing with on-site result printing, the MQW-511/411/311 series can be fitted with an optional internal or external microprinter.
Main Technical Specifications
Gas Measurement Ranges
| Model | HC | CO | CO₂ | NO | O₂ |
|---|---|---|---|---|---|
| MQW-50A | 0–9,999 ppm | 0–15% | 0–18% | 0–5,000 ppm | 0–25% |
| MQW-50B | 0–9,999 ppm | 0–15% | 0–18% | 0–5,000 ppm | 0–25% |
| MQW-5105 | 0–9,999 ppm | 0–15% | 0–18% | 0–5,000 ppm | 0–25% |
| MQW-5102 | — | — | 0–18% | 0–5,000 ppm | — |
For the 50A, 50B and 5105, HC and NO resolution is 1 ppm, while CO, CO₂ and O₂ resolution is 0.01%. The 5102 has CO₂ resolution of 0.01% and NO resolution of 1 ppm. A dash indicates a channel not listed for that model.
Main Units and Preconditioning Units
| Model/unit | Power consumption | Dimensions (L × W × H) | Weight |
|---|---|---|---|
| MQW-50A | 65 W | 440 × 485 × 230 mm | Approx. 15 kg |
| MQW-50B | 110 W | 440 × 485 × 230 mm | Approx. 16 kg |
| MQW-5105 main unit | 110 W | 440 × 485 × 230 mm | Approx. 16 kg |
| MQW-5105 preconditioning unit | 350 W | 530 × 380 × 145 mm | Approx. 12 kg |
| MQW-5102 main unit | 110 W | 440 × 485 × 230 mm | Approx. 16 kg |
| MQW-5102 preconditioning unit | 350 W | 530 × 380 × 145 mm | Approx. 12 kg |
| MQW-511/411/311 | 45 W | 240 × 248 × 210 mm | Approx. 8 kg |
The listed models operate on AC 220 V ±22 V, 50 Hz ±1 Hz. Warm-up time is 30 min for the 50A, 50B, 5105 and 5102, and 15 min for the 511/411/311 series.
Frequently Asked Questions
What Is the Main Difference Between the MQW-50A and MQW-50B?
Both provide five-gas measurement, but use different NO measurement principles: the 50A uses an electrochemical sensor, while the 50B uses non-dispersive infrared measurement. The 50A is intended for two-speed idle testing, and the 50B for steady-state testing.
Does the MQW-5102 Measure Smoke Directly?
The 5102 main unit measures CO₂ and NO. Exhaust opacity is measured by a connected MQY-202 opacity meter. This is a separate supporting instrument; the main unit's gas channels do not replace it.
Are the MQW-511, 411 and 311 All Five-Gas Analyzers?
The series name does not determine the gas channels. Specify the gases required and select the corresponding model configuration. The series supports standalone idle and two-speed idle testing, with optional printing.
Does NOx Conversion Provide an Independent NO₂ Channel?
No. The 5105 and 5102 convert NO₂ to NO before measurement. This differs from measuring NO₂ through an independent channel.
Contact Us
Tell Cartesy about the vehicle types, testing conditions, required gas channels and existing system connection. We can then discuss the appropriate model and supporting equipment.
Related Pages
Request a Quote
Request configuration and pricing for your project.
Share your vehicle type, inspection lane layout, target capacity, and required model configuration for Automotive Exhaust Gas Analyzer | MQW-50A/50B/5105/5102/511/411/311.
Share the project location, vehicle types, inspection scope, applicable standards, target throughput, site conditions and current stage. We will confirm the configuration scope before discussing pricing.